What’s New in This Release

Our valuable users have encouraged us with software improvements for a better user experience. Here is a quick look at the new developments for the NT8 4.5.

Software Improvements

A Selectable Protein Source Block in ROCK MAKER (RM) Integration to Support Your Needs

NT8-RM Integration has been improved for a better user experience. You can now easily select the Protein Source Block that suits your needs: High Volume Protein Block, Low Volume Protein Block, and High Volume Multi-Source Protein Block. A dialog box will appear once you enter the barcode of an experiment, allowing you to select the type of Protein Source Block most suitable for your needs. The NT8 Control Software also provides a recommendation of Protein Source Block based on the protein volume in your experiment.

Selectable Protein Source Block in RM Integration

Selectable Protein Source Block in RM Integration

Enhanced 24-Well Plate Dispensing Feature

  • Optimized Dispensing with Both Types of Protein Source Blocks

    Increase your 24-well plate dispensing performance by working with both types of Protein Blocks. You can aspirate from a standard Protein Block and a High Volume Multi-Source Protein Block on the same task list. Aspirating from both Protein Block types (the standard and the high volume multi-source ones) can facilitate you with more protein volumes for your experiment.

    Aspirating from Both Types of Protein Source Blocks for 24-well Plate Dispensing

    Aspirating from Both Types of Protein Source Blocks for 24-well Plate Dispensing

  • Easier 24-well Plate Dispensing

    When dispensing a 24-well plate, strikethroughs now appear to indicate which wells on the protein block are not available. This makes programming which well to aspirate protein from easier when working with 24-well plates.

    Strikethroughs Lining Up Each of the Unselected Well in the Software Interface

    Strikethroughs Lining Up Each of the Unselected Well in the Software Interface

    The software interface improvement also goes for the Deep Well and HV Tip Caddy Stations interface. The Deep Well and High Volume Tip Caddy stations you use to run the Plate Copy option are highlighted as “Unavailable” when using 24-well plate dispensing. This improvement aims to keep your NT8 hardware safe. A message informing you that both stations are not accessible is provided in each station to give you a visual cue that the Plate Copy option will not be available for 24-well plate dispensing.

    Note

    This improvement is only available for NT8 hardware purchases with the plate copy option.

    Redesigned Plate Copy Software Interface

    Redesigned Plate Copy Software Interface

A Redesigned Software Menu for Streamlined User Experience

NT8 4.5 comes with a redesigned Tools menu to make it easier for you to perform tasks. The Options, Touch Sensors, Calibrations, and Test Email options are categorized in a tidier section for your convenience. Find out more on Menu Bar.

Redesigned Tools Menu in the NT8 Control Software

Redesigned Tools Menu in the NT8 Control Software

Minor Software Changes

NT8 version 4.5 added several minor changes for your better usability including the following:

  • More Intuitive Auto Calibration Settings

    Your keyboard and mouse have been intensified to support your Auto Calibration Settings. Your keyboard arrow keys can be used to adjust the X, Y, and Z axes, and the scroll wheel on your mouse can be used to adjust the Speed in the Manual Control field.

    Adjusting the X, Y, and Z Axes with the Keyboard Arrow Keys

    Adjusting the X, Y, and Z Axes with the Keyboard Arrow Keys

    On top of all that, your keyboard and mouse have been configured to modify the X, Y, and Z axes instantly on the calibration result table. Click on either the X, Y, and Z axes and type the axes you think are more accurate.

    Adjusting the X, Y, and Z Axes in the Calibration Result Table

    Adjusting the X, Y, and Z Axes in the Calibration Result Table

  • A Reliable Data Backup Storage

    Enjoy a more secure data backup experience with the NT8 Control Software. When you install the NT8 Control Software for the first time, you can now select the data backup location that fits your needs: Default location or Custom location. Your backup data and live data will remain safe. Read more on Backup and Restore Data.

../_images/release_notes_button.png

Many of the best NT8 updates have been suggested by our awesome user community!

Have a great idea on how to make NT8 better? Let us know by contacting us at support@formulatrix.com.

Previous Releases

Version 4.4

An Improved Dispensing Feature: Accommodating 24-Well Plate Dispensing Needs

The NT8 hardware now supports 24-well plate dispensing, which includes both sitting drop and hanging drop experiments. The 24-well plate is particularly useful to scale up crystal size by setting up larger protein drop sizes. Moreover, it brings additional convenience during crystal harvesting when performing a hanging drop experiment, where crystals won’t bond to the bottom of the plates because of gravity. Take a look at the 24-well plate type below and its accompaniments:

24-Well Hanging Drop Plate (Hampton VDXm Plate)

24-Well Hanging Drop Plate (Hampton VDXm Plate)

The Glass Coverslip Adapter for 24-Well Hanging Drop Plate (For Hampton VDXm Plate)

The Glass Coverslip Adapter for 24-Well Hanging Drop Plate (For Hampton VDXm Plate)

24-Well Sitting Drop Plate

24-Well Sitting Drop Plate

For more streamlined experiments, the waste station is redesigned to accommodate the 4-tip ejection process, which is a critical sequence in 24-well plate dispensing. Go to V4 Hardware Overview.

The Redesigned Waste Station Design

The Redesigned Waste Station Design

Watch the video below to see how to set up a 24 Well VDXm Hanging Drop Experiment Plate.

Watch the video below to see how to set up a 24 Well Sitting Drop Experiment Plate.

NT8 Control Software Made More Versatile to Accommodate 24-Well Plate

Aside from the hardware, the NT8 Control Software has also been made more convenient to further support the use of 24-well plates. The software is improved in the following ways:

  • Optimized Plate Type Settings Following 24-well Plate Dispensing

    The New Plate Type wizard has also been optimized so you can modify the Number of Rows and Number of Columns in order to create a new plate definition for a 24-well plate type. To find out more, go to Adding and Editing Plate Types.

    Setting Up the 24-well Plate in the New Plate Type Wizard

    Setting Up the 24-well Plate in the New Plate Type Wizard

  • More Intuitive Waste Station Task

    For better usability, the NT8 Control Software will now automatically add a Prepare Tips task to cater for an aspirate task from a 4-row plate. This behavior appears after you add an aspirate task from 24-well plate. For more information, see Waste Station.

    Automatically Adding a Prepare Tips Task to Dispense to a 24-well Plate

    Automatically Adding a Prepare Tips Task to Dispense to a 24-well Plate

  • Enhanced the Protein Source Interface

    Every time you run an experiment using a 24-well plate, NT8 will show the confirmation message below to make sure you are only filling into the correct wells of the Protein Tray. This behavior also appears when you select this plate type for the first time on any Plate Stations. This helps prevent any protein loss. The Protein Source Station image on the software also has blue indicators to provide visual cues about which wells the tips are aspirating from.

    A Confirmation Message to Make Sure that The Protein was Filled in the Suitable Protein Well

    A Confirmation Message to Make Sure that The Protein was Filled in the Suitable Protein Well

    In the image below, the Protein Source on the right indicates only 4 tips attached for a dispense task into a 24-well plate.

    Aspirating from All of the 8 tips and Aspirating from 4 Tips
Version 4.3

NT8 4.3 provides you with both software and hardware improvements to help you run experiments smoother. Here’s a quick look at the new developments for NT8 4.3.

Hardware Improvements

(NT8 V4 Only) Reference Plate, Protein Block, and LV Tip Caddy Redesigns for a More Accurate Auto-Calibration Result

In NT8 4.3, several hardware components have been significantly improved to ensure greater accuracy for Auto-Calibration. The hardware redesign includes the following:

  • Enhanced Reference Plate with Deeper Grooves for Better Laser Scanning

    The Reference Plate enhancement includes simplifying the Auto-Calibration method. The shallow engraved lines which previously connected the A1, A12, H1, H12 points were replaced with deeper grooves to accommodate laser scanning for precise X, Y, and Z coordinates. This method ensures a more accurate reference point as it eliminates the offset calculation. Find out more in V4 Hardware Overview.

    Revamped Reference Plate

    Revamped Reference Plate

  • LV Tip Caddy Station for Better Protein Sample Aspiration

    Similar to the Reference Plate, the LV Tip Caddy has also been improved to ensure accurate Auto-Calibration results. The redesign includes two square grooves in the lower-left corner that provide direct reference points without having to use an offset calculation, thus ensuring calibration precision.

    The New LV Tip Caddy Design

    The New LV Tip Caddy Design

  • New Protein Block for More Precise Aspirate Experience

    The Protein Block has also been optimized to provide a more precise aspiration. There is no longer an offset calculation between the wall and target point. The laser scanning process now provides a precise reference point. Go to V4 Hardware Overview for further details.

    The New Protein Block Design

    The New Protein Block Design

Software Improvements

New Sleek User Interface for Auto-Calibration

NT8 4.3 brings a powerful new Auto-Calibration wizard to make it even easier to set up your system. The new wizard walks users through hardware setup to help you quickly choose which station needs calibration. We strive to make this process as simple as possible with no need to modify configuration files and type key values. Ensuring a precise aspirate and dispense experience can now be achieved in just a few clicks within this wizard. To access it, click the Tools menu, point to Calibration and select your desired option.

Warning

Please do not attempt to calibrate your NT8 without assistance from FORMULATRIX support.

The Auto-Calibration Wizard

The Auto-Calibration Wizard

Added Protein Block Type Option in ROCK MAKER Integration (RMI)

Now, you can select the Protein Block type directly from the RMI view upon loading the first experiment barcode. This streamlines the process and helps you save time as you no longer need to switch to the Task List View first to do so. Read more about the ROCK MAKER Integration.

Selecting the Protein Block Type in ROCK MAKER Integration

Selecting the Protein Block Type in ROCK MAKER Integration

Other Improvements

NT8 4.3 comes with several other improvements as follows:

  • You can now use all tips as the default in Auto-Calibration and Manual Calibration for more versatility.

  • Added a maximum capacity value of the chamber maximum capacity field to optimize the Calibration settings. This setting prevents water overflow during calibration.

Minor Software Changes

NT8 version 4.3 added several minor changes for better usability. The minor changes include the following:

  • (NT8 V4 Hardware Only) In NT8 4.3, the Wash Valve and Pump functions are integrated into one button in the Control Switches panel on the Script View. These features work simultaneously, thus using one button to activate them will boost your efficiency with the NT8.

    Integrated Wash Pump and Valve Button in the Control Switch Panel

    Integrated Wash Pump and Valve Button in the Control Switch Panel

  • Improved the display of the Plate Stations while running the task list so that only the selected drops and/or wells show the teal indicator as they are dispensed.

    Showing Teal Indicator in the Dispensed Wells

    Showing Teal Indicator in the Dispensed Wells