Release Notes¶
Version 4.11 BETA¶
Build Date: April 21, 2026¶
Added:
The RESET PREFERENCES button to the User Preferences and Group Preferences dialog boxes.
[Experiment Page] The Explore tab to allow double-clicking or dragging and dropping an item onto the Canvas to add a layer.
Support for more parameters for the importable batchload experiment CSV file.
Rock Maker Control Panel for service monitoring and Windows account configurations.
[Settings Menu] [Global Preferences Submenu] Separate label printing functionality to print experiment information to the Label Printing system property.
[Experiment Page] The loading spinner when opening an imaged experiment.
[Search and Filter] The Rows per page field to the Canvas, Drop, and Compare menus.
Support for new keyboard shortcuts in Search and Filter.
[ROCK MAKER-NT8 Integration] The ability to generate and relay ingredient and volume information for fragment screens.
[ROCK MAKER-NT8 Integration] The fragment screen dispensing support.
[Experiment Page] The Info toggle in the Tools panel to display information on drop images.
[Installer] The database backup and upgrade indicator during migration.
[Explore Menu] A Detail View option to the View dropdown in the top right bar.
[Experiment Page] The Fit to Plate button to the bottom bar of the Canvas menu.
Updated vendor screens for fresh installation.
[Experiment Page] Fragment information to the Well Ingredients submenu in the Canvas menu.
A Pan button to the bottom bar of the Canvas menu on the experiment page.
A Canvas Map button to the Navigator panel in the Drop, Well, and Compare menus on the experiment page.
A confirmation message when navigating away from the Experiment, Search and Filter, and Synchrotron Trip pages with unsaved changes.
The Download Protein Template link to the New Protein Formulation tab and Create Protein Variant dialog box.
[Experiment Page] [Tools] A box around the crystal length text of the Ruler in drop images.
A progress indicator to the Batchload Experiment Wizard during batchload file upload.
The Def. Fragment Vol. column to the Plate Types submenu in the Setup menu.
[Licensing] Support for ROCK MAKER Lite license feature.
A notification to inform users when ROCK MAKER is busy and cannot run another task.
[Optimization Wizard] A notification to inform users when selected wells for optimization exceed the number of target wells.
Improved:
User-facing error messages for various different exceptions.
[Experiment Page] The image viewing user experience by prioritizing canvas thumbnail image loading.
[Experiment Page] Breadcrumbs to display full experiment names.
Multiple-selection for right click in the Explore menu.
The error message for a failed SMTP configuration.
[Search and Filter] The error message when saving an existing search and filter file name.
[Setup Menu] [Imaging Submenu] A combinator in the Filters section of the Image Management Task tab.
[Explore Menu] The experiment information side panel to display protein name, concentration, and screen name.
[Experiment Page] [Fragment Layer] The Layers Design panel to automatically display the list of fragment screens during a fragment layer creation.
[Setup Menu] [Imaging Submenu [Image Management Task] The Filters section by merging BASIC and ADVANCED filters.
[ROCK MAKER Lite] The image saving feature to save all images of an inspection at once.
Changed:
Seat License validation mechanism to use a Windows-based authenticator application to validate the license from the server.
NEW FOLDER and NEW PROJECT buttons from the bottom to the top bar of the Define Location section in the Optimization Wizard.
The distinct rows option position from the Filter panel to the bottom bar of the Search and Filter page.
[Explore Menu] [Searches Node] The New Search Folder right click option in blank space to New Folder.
[Experiment Page] The Score button position from the top bar to the submenu bar below the Design, Image, and Well Ingredients submenus in the Canvas menu.
[Experiment Page] [Manual Scoring] The Assigning [] Score(s) progress bar to Applying [] Score(s).
Fixed:
[Search and Filter] The unapplied drop selection from the Result menu to the one highlighted in the Canvas menu.
[Experiment Page] [Compare Menu] The mismatch drop information in the Well and Compare menus.
[Experiment Page] The skipped Image submenu in the Canvas menu when navigating through submenus in an unimaged experiment.
[Experiment Page] The overlapping plate with the side panel in the Canvas menu when opening an experiment with multiple plates.
[Experiment Page] The changing compare view to a single drop image when switching regions, drops, or inspections in the Compare menu.
Software accessibility during a stopped service state due to the running RockMaker.exe file in the Task Manager.
A keyboard shortcut selecting items outside of the Rename Item dialog box when working with the text inside the dialog box.
[Mouse Click] The malfunctioning left click when double-clicking a folder and its subfolder simultaneously.
[Canvas Menu] The undisplayed plates in an experiment with more than 25 plates.
[Experiment Page] [Drop Menu] An error when navigating through drop images quickly.
[Experiment Page] The unresized Canvas menu when maximizing or minimizing the browser window.
[Experiment Page] The changing compare view to a single drop image when selecting a different inspection in an experiment with multiple inspections.
[Experiment Design] [Layers Design] The incorrect Grid and Linked layer order in the layer list.
[Search and Filter] The malfunctioning column sorting in the Result menu.
[Crystal Harvesting] The failure to harvest a crystal in an ROI.
[Search and Filter] [Result Menu] The automatic scroll back to the previously selected row after selecting another one in the table.
The imaging schedule related warning message appearing when saving an experiment with a customized schedule.
The failure to delete an in-use imaging schedule, triggering an error message.
[Experiment Page] [Image Tools] The misaligned Ruler’s dot and line.
The flickering interface of projects and folders in the Explore menu during batchload experiment creation.
[Experiment Page] The ingredient concentrations with more than two decimal digits in the Find Drops panel.
An error when deleting an image management task.
[Recycle Bin] The failure to restore a folder and its subfolder simultaneously.
[Performance] [Experiment Page] [Canvas Menu] The laggy zoom-in or zoom-out in an experiment with enabled Image Tuning.
The one experiment ID gap in the experiment names generated by the Batchload Experiment Wizard.
The failure to register newly-imaged drops for auto scoring schedule due to network issues during image processing.
[Optimization Wizard] An error when optimizing an original experiment with more wells than the optimized experiment.
An encryption operation failure due to domain account changes causing the software to display a 500 internal Server Error message.
The Single Drop Report displaying the last inspected image instead of the selected one.
The Well Report displaying the last inspected image instead of the selected one.
[Batchload Experiment] The multiple proteins generated from a protein name containing brackets in the batchload file.
An error when opening the General submenu of the Setup menu due to user configuration issues.
The crystal notification emailed to the support team instead of the experiment owner.
[Experiment Page] [Performance] The slow image loading.
[Search and Filter] Well numbers labelled as undefined in the Drop and Compare menus for experiments with a large number of wells.
The barcode printing issue, properly printing only 4 plate barcodes instead of all barcodes generated by the Batchload Experiment Wizard.
The incorrect online help link in the Import Protein dialog box.
[Experiment Page] [Info Panel] The undisplayed protein details in the Protein tab of the Ingredient Info once added to a layer.
[Experiment Page] [Canvas Menu] The undisplayed Drop button in the bottom bar of the Design submenu.
[Screen Import] The stockConcentration error message appearing after selecting Use Substitute Ingredient and clicking the IMPORT button in the Import Ingredients Options dialog box with a conflicting ingredient.
[ROCK MAKER-ROCK IMAGER Integration] Imported focus levels although the Enable Import Focus Level toggle button in the Focus Level panel was disabled.
A log error when opening an experiment with deleted images.
[ROCK IMAGER Processor] [Image Processing] The intermittent failure to process images due to deadlocked database transactions.
[Image Management Task] The failure to permanently delete experiments containing a hanging imaging task status.